+91-7207552499
Mon - Sat : 9AM - 6PM
JK EMS
PRODUCTS
Adaptors for Coffee Vending Machine
At JK EMS Solutions, we're dedicated to providing top-notch coffee vending machine adapters. We offer a wide selection of adapters designed to meet the exact power needs of any tea, coffee, or vending machine you might have. No matter the machine or beverage, we have an adapter to ensure it runs smoothly. Our adapters are built with the latest technology, making them efficient and long-lasting. They're also compact and lightweight, so they'll easily fit into any vending machine setup. Thanks to this innovative design, our adapters work flawlessly in any environment around the world, regardless of local power conditions or climate. We use only the highest-quality, trusted materials in every adapter, so you can be confident they're built to last.
Salient Features

Wide Input Voltage Range
Operates efficiently within 150VAC-280VAC
Energy Efficiency
Very low no-load power consumption
High Inductive Load Capacity
Capable of starting high inductive loads, such as vending machine motors
Thermal Management
Thermal shutdown at 130°C with automatic restart upon cooling
Smooth Operation
Soft start feature and low inrush current
Robust Isolation
Provides isolation up to 3kV for 5 seconds
Input Specifications
Input Operating AC Voltage

150 - 280 VAC

Input Operating Frequency

50 - 60 Hz

Input AC current

1.12A @ 150 VAC

Input Power

123.50 W

Output Specifications
Output DC Voltage

22.8 - 25.2 VDC

Output Rated Current

4.2 A

Output Over Current

> 10.0 A

Ouput Power

101.30 W

Efficiency:
Input Voltage (V) Input Current (A) Input Power (Watts) Output Voltage (V) Output Current (A) Output Power (Watts) Efficiency %
150 1.12 123.50 24.12 4.20 101.30 82.03
200 0.96 121.70 24.12 4.20 101.30 83.24
230 0.87 119.80 24.12 4.20 101.30 84.56
250 0.80 119.90 24.12 4.20 101.30 84.49
280 0.71 120.10 24.12 4.20 101.30 84.35
Electrical Integrity Testing:
Test Condition Result
High Voltage Break-down Test 3000VACrms for 1min. applied between Shorted Input & Shorted Output terminals with a trip current of 5mA OK
Insulation Resistance Test 500VDC applied between shorted INPUT and OUTPUT terminals for 60 Sec. duration. The insulation resistance shall not be > 100 M ohm 110 M ohm